using HslCommunication.BasicFramework;
using HslCommunication.Core;
using HslCommunication.Core.Address;
using HslCommunication.Core.IMessage;
using HslCommunication.Core.Net;
using System;
using System.Collections.Generic;
using System.Net.Sockets;
using System.Text;

/********************************************************************************
 * 
 *    说明:西门子通讯类,使用S7消息解析规格,和反字节转换规格来实现的
 *    
 *    继承自统一的自定义方法
 *    其中的启动,停止的功能代码参考了开源项目:https://github.com/fbarresi/Sharp7
 * 
 *********************************************************************************/




namespace HslCommunication.Profinet.Siemens
{
    /// <summary>
    /// 一个西门子的客户端类,使用S7协议来进行数据交互 ->
    /// A Siemens client class that uses the S7 protocol for data interaction
    /// </summary>
    /// <remarks>
    /// 地址支持的列表如下:
    /// <list type="table">
    ///   <listheader>
    ///     <term>地址名称</term>
    ///     <term>地址代号</term>
    ///     <term>示例</term>
    ///     <term>地址进制</term>
    ///     <term>字操作</term>
    ///     <term>位操作</term>
    ///     <term>备注</term>
    ///   </listheader>
    ///   <item>
    ///     <term>中间寄存器</term>
    ///     <term>M</term>
    ///     <term>M100,M200</term>
    ///     <term>10</term>
    ///     <term>√</term>
    ///     <term>√</term>
    ///     <term></term>
    ///   </item>
    ///   <item>
    ///     <term>输入寄存器</term>
    ///     <term>I</term>
    ///     <term>I100,I200</term>
    ///     <term>10</term>
    ///     <term>√</term>
    ///     <term>√</term>
    ///     <term></term>
    ///   </item>
    ///   <item>
    ///     <term>输出寄存器</term>
    ///     <term>Q</term>
    ///     <term>Q100,Q200</term>
    ///     <term>10</term>
    ///     <term>√</term>
    ///     <term>√</term>
    ///     <term></term>
    ///   </item>
    ///   <item>
    ///     <term>DB块寄存器</term>
    ///     <term>DB</term>
    ///     <term>DB1.100,DB1.200</term>
    ///     <term>10</term>
    ///     <term>√</term>
    ///     <term>√</term>
    ///     <term></term>
    ///   </item>
    ///   <item>
    ///     <term>V寄存器</term>
    ///     <term>V</term>
    ///     <term>V100,V200</term>
    ///     <term>10</term>
    ///     <term>√</term>
    ///     <term>√</term>
    ///     <term>V寄存器本质就是DB块1</term>
    ///   </item>
    ///   <item>
    ///     <term>定时器的值</term>
    ///     <term>T</term>
    ///     <term>T100,T200</term>
    ///     <term>10</term>
    ///     <term>√</term>
    ///     <term>√</term>
    ///     <term>未测试通过</term>
    ///   </item>
    ///   <item>
    ///     <term>计数器的值</term>
    ///     <term>C</term>
    ///     <term>C100,C200</term>
    ///     <term>10</term>
    ///     <term>√</term>
    ///     <term>√</term>
    ///     <term>未测试通过</term>
    ///   </item>
    /// </list>
    /// <note type="important">对于200smartPLC的V区,就是DB1.X,例如,V100=DB1.100</note>
    /// </remarks>
    /// <example>
    /// <code lang="cs" source="HslCommunication_Net45.Test\Documentation\Samples\Profinet\SiemensS7Net.cs" region="Usage" title="简单的短连接使用" />
    /// <code lang="cs" source="HslCommunication_Net45.Test\Documentation\Samples\Profinet\SiemensS7Net.cs" region="Usage2" title="简单的长连接使用" />
    /// </example>
    public class SiemensS7Net : NetworkDeviceBase<S7Message, ReverseBytesTransform>
    {
        #region Constructor

        /// <summary>
        /// 实例化一个西门子的S7协议的通讯对象 ->
        /// Instantiate a communication object for a Siemens S7 protocol
        /// </summary>
        /// <param name="siemens">指定西门子的型号</param>
        public SiemensS7Net(SiemensPLCS siemens)
        {
            Initialization(siemens, string.Empty);
        }

        /// <summary>
        /// 实例化一个西门子的S7协议的通讯对象并指定Ip地址 ->
        /// Instantiate a communication object for a Siemens S7 protocol and specify an IP address
        /// </summary>
        /// <param name="siemens">指定西门子的型号</param>
        /// <param name="ipAddress">Ip地址</param>
        public SiemensS7Net(SiemensPLCS siemens, string ipAddress)
        {
            Initialization(siemens, ipAddress);
        }

        /// <summary>
        /// 初始化方法 -> Initialize method
        /// </summary>
        /// <param name="siemens">指定西门子的型号 -> Designation of Siemens</param>
        /// <param name="ipAddress">Ip地址 -> IpAddress</param>
        private void Initialization(SiemensPLCS siemens, string ipAddress)
        {
            WordLength = 2;
            IpAddress = ipAddress;
            Port = 102;
            CurrentPlc = siemens;

            switch (siemens)
            {
                case SiemensPLCS.S1200: plcHead1[21] = 0; break;
                case SiemensPLCS.S300: plcHead1[21] = 2; break;
                case SiemensPLCS.S400: plcHead1[21] = 3; plcHead1[17] = 0x00; break;
                case SiemensPLCS.S1500: plcHead1[21] = 0; break;
                case SiemensPLCS.S200Smart:
                    {
                        plcHead1 = plcHead1_200smart;
                        plcHead2 = plcHead2_200smart;
                        break;
                    }
                case SiemensPLCS.S200:
                    {
                        plcHead1 = plcHead1_200;
                        plcHead2 = plcHead2_200;
                        break;
                    }
                default: plcHead1[18] = 0; break;
            }
        }

        /// <summary>
        /// PLC的槽号,针对S7-400的PLC设置的
        /// </summary>
        public byte Slot
        {
            get => plc_slot;
            set
            {
                plc_slot = value;
                plcHead1[21] = (byte)((this.plc_rack * 0x20) + this.plc_slot);
            }
        }

        /// <summary>
        /// PLC的机架号,针对S7-400的PLC设置的
        /// </summary>
        public byte Rack
        {
            get => plc_rack;
            set
            {
                this.plc_rack = value;
                plcHead1[21] = (byte)((this.plc_rack * 0x20) + this.plc_slot);
            }
        }

        #endregion

        #region NetworkDoubleBase Override

        /// <summary>
        /// 连接上服务器后需要进行的二次握手操作 -> Two handshake actions required after connecting to the server
        /// </summary>
        /// <param name="socket">网络套接字 -> Network sockets</param>
        /// <returns>是否初始化成功,依据具体的协议进行重写 ->
        /// Whether the initialization succeeds and is rewritten according to the specific protocol</returns>
        protected override OperateResult InitializationOnConnect(Socket socket)
        {
            // 第一次握手 -> First handshake
            OperateResult<byte[]> read_first = ReadFromCoreServer(socket, plcHead1);
            if (!read_first.IsSuccess) return read_first;

            // 第二次握手 -> Second handshake
            OperateResult<byte[]> read_second = ReadFromCoreServer(socket, plcHead2);
            if (!read_second.IsSuccess) return read_second;

            // 返回成功的信号 -> Return a successful signal
            return OperateResult.CreateSuccessResult();
        }

        #endregion

        #region Read OrderNumber

        /// <summary>
        /// 从PLC读取订货号信息 -> Reading order number information from PLC
        /// </summary>
        /// <returns>CPU的订货号信息 -> Order number information for the CPU</returns>
        public OperateResult<string> ReadOrderNumber()
        {
            OperateResult<byte[]> read = ReadFromCoreServer(plcOrderNumber);
            if (!read.IsSuccess) return OperateResult.CreateFailedResult<string>(read);

            return OperateResult.CreateSuccessResult(Encoding.ASCII.GetString(read.Content, 71, 20));
        }

        #endregion

        #region Start Stop

        /// <summary>
        /// 对PLC进行热启动
        /// </summary>
        /// <returns>是否启动成功的结果对象</returns>
        public OperateResult HotStart()
        {
            OperateResult<byte[]> read = ReadFromCoreServer(S7_HOT_START);
            if (!read.IsSuccess) return read;

            if (read.Content.Length < 19) return new OperateResult("Receive error");

            if (read.Content[19] != pduStart) return new OperateResult("Can not start PLC");
            else if (read.Content[20] != pduAlreadyStarted) return new OperateResult("Can not start PLC");

            return OperateResult.CreateSuccessResult();
        }

        /// <summary>
        /// 对PLC进行冷启动
        /// </summary>
        /// <returns>是否启动成功的结果对象</returns>
        public OperateResult ColdStart()
        {
            OperateResult<byte[]> read = ReadFromCoreServer(S7_COLD_START);
            if (!read.IsSuccess) return read;

            if (read.Content.Length < 19) return new OperateResult("Receive error");

            if (read.Content[19] != pduStart) return new OperateResult("Can not start PLC");
            else if (read.Content[20] != pduAlreadyStarted) return new OperateResult("Can not start PLC");

            return OperateResult.CreateSuccessResult();
        }

        /// <summary>
        /// 对PLC进行停止
        /// </summary>
        /// <returns>是否启动成功的结果对象</returns>
        public OperateResult Stop()
        {
            OperateResult<byte[]> read = ReadFromCoreServer(S7_STOP);
            if (!read.IsSuccess) return read;

            if (read.Content.Length < 19) return new OperateResult("Receive error");

            if (read.Content[19] != pduStop) return new OperateResult("Can not stop PLC");
            else if (read.Content[20] != pduAlreadyStopped) return new OperateResult("Can not stop PLC");

            return OperateResult.CreateSuccessResult();
        }

        #endregion

        #region Read Support

        /// <summary>
        /// 从PLC读取数据,地址格式为I100,Q100,DB20.100,M100,T100,C100以字节为单位 ->
        /// Read data from PLC, address format I100,Q100,DB20.100,M100,T100,C100 in bytes
        /// </summary>
        /// <param name="address">起始地址,格式为I100,M100,Q100,DB20.100 ->
        /// Starting address, formatted as I100,M100,Q100,DB20.100</param>
        /// <param name="length">读取的数量,以字节为单位 -> The number of reads, in bytes</param>
        /// <returns>是否读取成功的结果对象 -> Whether to read the successful result object</returns>
        /// <remarks>
        /// <note type="important">对于200smartPLC的V区,就是DB1.X,例如,V100=DB1.100</note>
        /// </remarks>
        /// <example>
        /// 假设起始地址为M100,M100存储了温度,100.6℃值为1006,M102存储了压力,1.23Mpa值为123,M104,M105,M106,M107存储了产量计数,读取如下:
        /// <code lang="cs" source="HslCommunication_Net45.Test\Documentation\Samples\Profinet\SiemensS7Net.cs" region="ReadExample2" title="Read示例" />
        /// 以下是读取不同类型数据的示例
        /// <code lang="cs" source="HslCommunication_Net45.Test\Documentation\Samples\Profinet\SiemensS7Net.cs" region="ReadExample1" title="Read示例" />
        /// </example>
        public override OperateResult<byte[]> Read(string address, ushort length)
        {
            OperateResult<S7AddressData> addressResult = S7AddressData.ParseFrom(address, length);
            if (!addressResult.IsSuccess) return OperateResult.CreateFailedResult<byte[]>(addressResult);

            // 如果长度超过200,分批次读取 -> If the length is more than 200, read in batches
            List<byte> bytesContent = new List<byte>();
            ushort alreadyFinished = 0;
            while (alreadyFinished < length)
            {
                ushort readLength = (ushort)Math.Min(length - alreadyFinished, 200);
                addressResult.Content.Length = readLength;
                OperateResult<byte[]> read = Read(new S7AddressData[] { addressResult.Content });
                if (!read.IsSuccess) return read;

                bytesContent.AddRange(read.Content);
                alreadyFinished += readLength;
                addressResult.Content.AddressStart += readLength * 8;
            }

            return OperateResult.CreateSuccessResult(bytesContent.ToArray());
        }

        /// <summary>
        /// 从PLC读取数据,地址格式为I100,Q100,DB20.100,M100,以位为单位 ->
        /// Read the data from the PLC, the address format is I100,Q100,DB20.100,M100, in bits units
        /// </summary>
        /// <param name="address">起始地址,格式为I100,M100,Q100,DB20.100 ->
        /// Starting address, formatted as I100,M100,Q100,DB20.100</param>
        /// <returns>是否读取成功的结果对象 -> Whether to read the successful result object</returns>
        private OperateResult<byte[]> ReadBitFromPLC(string address)
        {
            // 指令生成 -> Build bit read command
            OperateResult<byte[]> command = BuildBitReadCommand(address);
            if (!command.IsSuccess) return OperateResult.CreateFailedResult<byte[]>(command);

            // 核心交互 ->  Core interactive
            OperateResult<byte[]> read = ReadFromCoreServer(command.Content);
            if (!read.IsSuccess) return read;

            // 分析结果 -> Analysis read result
            int receiveCount = 1;
            if (read.Content.Length >= 21 && read.Content[20] == 1)
            {
                byte[] buffer = new byte[receiveCount];
                if (22 < read.Content.Length)
                {
                    if (read.Content[21] == 0xFF &&
                        read.Content[22] == 0x03)
                    {
                        buffer[0] = read.Content[25];
                    }
                }

                return OperateResult.CreateSuccessResult(buffer);
            }
            else
            {
                return new OperateResult<byte[]>(read.ErrorCode, StringResources.Language.SiemensDataLengthCheckFailed);
            }
        }


        /// <summary>
        /// 一次性从PLC获取所有的数据,按照先后顺序返回一个统一的Buffer,需要按照顺序处理,两个数组长度必须一致,数组长度无限制 ->
        /// One-time from the PLC to obtain all the data, in order to return a unified buffer, need to be processed sequentially, two array length must be consistent
        /// </summary>
        /// <param name="address">起始地址,格式为I100,M100,Q100,DB20.100 ->
        /// Starting address, formatted as I100,M100,Q100,DB20.100</param>
        /// <param name="length">数据长度数组 -> Array of data Lengths</param>
        /// <returns>是否读取成功的结果对象 -> Whether to read the successful result object</returns>
        /// <exception cref="NullReferenceException"></exception>
        /// <remarks>
        /// <note type="warning">原先的批量的长度为19,现在已经内部自动处理整合,目前的长度为任意和长度。</note>
        /// </remarks>
        /// <example>
        /// 参照<see cref="Read(string, ushort)"/>
        /// </example>
        public OperateResult<byte[]> Read(string[] address, ushort[] length)
        {
            S7AddressData[] addressResult = new S7AddressData[address.Length];
            for (int i = 0; i < address.Length; i++)
            {
                OperateResult<S7AddressData> tmp = S7AddressData.ParseFrom(address[i], length[i]);
                if (!tmp.IsSuccess) return OperateResult.CreateFailedResult<byte[]>(tmp);

                addressResult[i] = tmp.Content;
            }

            return Read(addressResult);
        }

        /// <summary>
        /// 读取西门子的地址数据信息,支持任意个数的数据读取 ->
        /// Read Siemens address data information, support any number of data reading
        /// </summary>
        /// <param name="s7Addresses">西门子的数据地址 -> Siemens data address</param>
        /// <returns>返回的结果对象信息 -> Whether to read the successful result object</returns>
        public OperateResult<byte[]> Read(S7AddressData[] s7Addresses)
        {
            if (s7Addresses.Length > 19)
            {
                List<byte> bytes = new List<byte>();
                List<S7AddressData[]> groups = SoftBasic.ArraySplitByLength<S7AddressData>(s7Addresses, 19);
                for (int i = 0; i < groups.Count; i++)
                {
                    OperateResult<byte[]> read = Read(groups[i]);
                    if (!read.IsSuccess) return read;

                    bytes.AddRange(read.Content);
                }
                return OperateResult.CreateSuccessResult(bytes.ToArray());
            }
            else
            {
                return ReadS7AddressData(s7Addresses);
            }
        }

        /// <summary>
        /// 单次的读取,只能读取最多19个数组的长度,所以不再对外公开该方法
        /// </summary>
        /// <param name="s7Addresses">西门子的地址对象</param>
        /// <returns>返回的结果对象信息</returns>
        private OperateResult<byte[]> ReadS7AddressData(S7AddressData[] s7Addresses)
        {
            // 构建指令 -> Build read command
            OperateResult<byte[]> command = BuildReadCommand(s7Addresses);
            if (!command.IsSuccess) return command;

            // 核心交互 -> Core Interactions
            OperateResult<byte[]> read = ReadFromCoreServer(command.Content);
            if (!read.IsSuccess) return read;

            // 分析结果 -> Analysis results
            int receiveCount = 0;
            for (int i = 0; i < s7Addresses.Length; i++)
            {
                receiveCount += s7Addresses[i].Length;
            }

            if (read.Content.Length >= 21 && read.Content[20] == s7Addresses.Length)
            {
                byte[] buffer = new byte[receiveCount];
                int kk = 0;
                int ll = 0;
                for (int ii = 21; ii < read.Content.Length; ii++)
                {
                    if ((ii + 1) < read.Content.Length)
                    {
                        if (read.Content[ii] == 0xFF &&
                            read.Content[ii + 1] == 0x04)
                        {
                            Array.Copy(read.Content, ii + 4, buffer, ll, s7Addresses[kk].Length);
                            ii += s7Addresses[kk].Length + 3;
                            ll += s7Addresses[kk].Length;
                            kk++;
                        }
                        else if (read.Content[ii] == 0x05 &&
                            read.Content[ii + 1] == 0x00)
                        {
                            return new OperateResult<byte[]>(read.Content[ii], StringResources.Language.SiemensReadLengthOverPlcAssign);
                        }
                    }
                }

                return OperateResult.CreateSuccessResult(buffer);
            }
            else
            {
                return new OperateResult<byte[]>(read.ErrorCode, StringResources.Language.SiemensDataLengthCheckFailed);
            }
        }

        /// <summary>
        /// 读取指定地址的bool数据,地址格式为I100,M100,Q100,DB20.100 -> 
        /// reads bool data for the specified address in the format I100,M100,Q100,DB20.100
        /// </summary>
        /// <param name="address">起始地址,格式为I100,M100,Q100,DB20.100 ->
        /// Starting address, formatted as I100,M100,Q100,DB20.100</param>
        /// <returns>是否读取成功的结果对象 -> Whether to read the successful result object</returns>
        /// <remarks>
        /// <note type="important">
        /// 对于200smartPLC的V区,就是DB1.X,例如,V100=DB1.100
        /// </note>
        /// </remarks>
        /// <example>
        /// 假设读取M100.0的位是否通断
        /// <code lang="cs" source="HslCommunication_Net45.Test\Documentation\Samples\Profinet\SiemensS7Net.cs" region="ReadBool" title="ReadBool示例" />
        /// </example>
        public override OperateResult<bool> ReadBool(string address)
        {
            return ByteTransformHelper.GetResultFromBytes(ReadBitFromPLC(address), m => m[0] != 0x00);
        }

        /// <summary>
        /// 读取指定地址的byte数据,地址格式I100,M100,Q100,DB20.100 ->
        /// Reads the byte data of the specified address, the address format I100,Q100,DB20.100,M100
        /// </summary>
        /// <param name="address">起始地址,格式为I100,M100,Q100,DB20.100 ->
        /// Starting address, formatted as I100,M100,Q100,DB20.100</param>
        /// <returns>是否读取成功的结果对象 -> Whether to read the successful result object</returns>
        /// <example>参考<see cref="Read(string, ushort)"/>的注释</example>
        public OperateResult<byte> ReadByte(string address)
        {
            return ByteTransformHelper.GetResultFromArray(Read(address, 1));
        }

        #endregion

        #region Write Base

        /// <summary>
        /// 基础的写入数据的操作支持 -> Operational support for the underlying write data
        /// </summary>
        /// <param name="entireValue">完整的字节数据 -> Full byte data</param>
        /// <returns>是否写入成功的结果对象 -> Whether to write a successful result object</returns>
        private OperateResult WriteBase(byte[] entireValue)
        {
            OperateResult<byte[]> write = ReadFromCoreServer(entireValue);
            if (!write.IsSuccess) return write;

            if (write.Content[write.Content.Length - 1] != 0xFF)
            {
                // 写入异常 -> WriteError
                return new OperateResult(write.Content[write.Content.Length - 1], StringResources.Language.SiemensWriteError + write.Content[write.Content.Length - 1]);
            }
            else
            {
                return OperateResult.CreateSuccessResult();
            }
        }

        /// <summary>
        /// 将数据写入到PLC数据,地址格式为I100,Q100,DB20.100,M100,以字节为单位 ->
        /// Writes data to the PLC data, in the address format I100,Q100,DB20.100,M100, in bytes
        /// </summary>
        /// <param name="address">起始地址,格式为I100,M100,Q100,DB20.100 ->
        /// Starting address, formatted as I100,M100,Q100,DB20.100</param>
        /// <param name="value">写入的原始数据 -> Raw data written to</param>
        /// <returns>是否写入成功的结果对象 -> Whether to write a successful result object</returns>
        /// <example>
        /// 假设起始地址为M100,M100,M101存储了温度,100.6℃值为1006,M102,M103存储了压力,1.23Mpa值为123,M104-M107存储了产量计数,写入如下:
        /// <code lang="cs" source="HslCommunication_Net45.Test\Documentation\Samples\Profinet\SiemensS7Net.cs" region="WriteExample2" title="Write示例" />
        /// 以下是写入不同类型数据的示例
        /// <code lang="cs" source="HslCommunication_Net45.Test\Documentation\Samples\Profinet\SiemensS7Net.cs" region="WriteExample1" title="Write示例" />
        /// </example>
        public override OperateResult Write(string address, byte[] value)
        {
            OperateResult<S7AddressData> analysis = S7AddressData.ParseFrom(address);
            if (!analysis.IsSuccess) return OperateResult.CreateFailedResult<byte[]>(analysis);

            int length = value.Length;
            ushort alreadyFinished = 0;
            while (alreadyFinished < length)
            {
                ushort writeLength = (ushort)Math.Min(length - alreadyFinished, 200);
                byte[] buffer = ByteTransform.TransByte(value, alreadyFinished, writeLength);

                OperateResult<byte[]> command = BuildWriteByteCommand(analysis, buffer);
                if (!command.IsSuccess) return command;

                OperateResult write = WriteBase(command.Content);
                if (!write.IsSuccess) return write;

                alreadyFinished += writeLength;
                analysis.Content.AddressStart += writeLength * 8;
            }

            return OperateResult.CreateSuccessResult();
        }

        /// <summary>
        /// 写入PLC的一个位,例如"M100.6","I100.7","Q100.0","DB20.100.0",如果只写了"M100"默认为"M100.0" ->
        /// Write a bit of PLC, for example  "M100.6",  "I100.7",  "Q100.0",  "DB20.100.0", if only write  "M100" defaults to  "M100.0"
        /// </summary>
        /// <param name="address">起始地址,格式为"M100.6",  "I100.7",  "Q100.0",  "DB20.100.0" ->
        /// Start address, format  "M100.6",  "I100.7",  "Q100.0",  "DB20.100.0"</param>
        /// <param name="value">写入的数据,True或是False -> Writes the data, either True or False</param>
        /// <returns>是否写入成功的结果对象 -> Whether to write a successful result object</returns>
        /// <example>
        /// 假设写入M100.0的位是否通断
        /// <code lang="cs" source="HslCommunication_Net45.Test\Documentation\Samples\Profinet\SiemensS7Net.cs" region="WriteBool" title="WriteBool示例" />
        /// </example>
        public override OperateResult Write(string address, bool value)
        {
            // 生成指令 -> Build Command
            OperateResult<byte[]> command = BuildWriteBitCommand(address, value);
            if (!command.IsSuccess) return command;

            return WriteBase(command.Content);
        }

        /// <summary>
        /// 向PLC中写入bool数组,比如你写入M100,那么data[0]对应M100.0 ->
        /// Write the bool array to the PLC, for example, if you write M100, then data[0] corresponds to M100.0
        /// </summary>
        /// <param name="address">起始地址,格式为I100,M100,Q100,DB20.100 -> Starting address, formatted as I100,mM100,Q100,DB20.100</param>
        /// <param name="values">要写入的bool数组,长度为8的倍数 -> The bool array to write, a multiple of 8 in length</param>
        /// <returns>是否写入成功的结果对象 -> Whether to write a successful result object</returns>
        /// <remarks>
        /// <note type="warning">
        /// 批量写入bool数组存在一定的风险,原因是只能批量写入长度为8的倍数的数组,否则会影响其他的位的数据,请谨慎使用。
        /// </note>
        /// </remarks>
        public override OperateResult Write(string address, bool[] values)
        {
            return Write(address, SoftBasic.BoolArrayToByte(values));
        }

        #endregion

        #region Write Byte

        /// <summary>
        /// 向PLC中写入byte数据,返回值说明 -> Write byte data to the PLC, return value description
        /// </summary>
        /// <param name="address">起始地址,格式为I100,M100,Q100,DB20.100 -> Starting address, formatted as I100,mM100,Q100,DB20.100</param>
        /// <param name="value">byte数据 -> Byte data</param>
        /// <returns>是否写入成功的结果对象 -> Whether to write a successful result object</returns>
        public OperateResult Write(string address, byte value)
        {
            return Write(address, new byte[] { value });
        }

        #endregion

        #region ReadWrite String

        /// <summary>
        /// 向设备中写入字符串,编码格式为ASCII
        /// </summary>
        /// <param name="address">数据地址</param>
        /// <param name="value">字符串数据</param>
        /// <returns>是否写入成功的结果对象</returns>
        /// <example>
        /// 以下为三菱的连接对象示例,其他的设备读写情况参照下面的代码:
        /// <code lang="cs" source="HslCommunication_Net45.Test\Documentation\Samples\Core\NetworkDeviceBase.cs" region="WriteString" title="String类型示例" />
        /// </example>
        public override OperateResult Write(string address, string value)
        {
            if (value == null) value = string.Empty;

            byte[] buffer = Encoding.ASCII.GetBytes(value);
            if (CurrentPlc != SiemensPLCS.S200Smart)
            {
                // need read one time
                OperateResult<byte[]> readLength = Read(address, 2);
                if (!readLength.IsSuccess) return readLength;

                if (readLength.Content[0] == 255) return new OperateResult<string>("Value in plc is not string type");
                if (readLength.Content[0] == 0) readLength.Content[0] = 254; // allow to create new string
                if (value.Length > readLength.Content[0]) return new OperateResult<string>("String length is too long than plc defined");

                return Write(address, SoftBasic.SpliceTwoByteArray(new byte[] { readLength.Content[0], (byte)buffer.Length }, buffer));
            }
            else
            {
                return Write(address, SoftBasic.SpliceTwoByteArray(new byte[] { (byte)buffer.Length }, buffer));
            }
        }

        /// <summary>
        /// 读取西门子的地址的字符串信息,这个信息是和西门子绑定在一起,长度随西门子的信息动态变化的
        /// </summary>
        /// <param name="address">数据地址,具体的格式需要参照类的说明文档</param>
        /// <returns>带有是否成功的字符串结果类对象</returns>
        public OperateResult<string> ReadString(string address)
        {
            if (CurrentPlc != SiemensPLCS.S200Smart)
            {
                var read = Read(address, 2);
                if (!read.IsSuccess) return OperateResult.CreateFailedResult<string>(read);

                if (read.Content[0] == 0 || read.Content[0] == 255) return new OperateResult<string>("Value in plc is not string type");    // max string length can't be zero

                var readString = Read(address, (ushort)(2 + read.Content[1]));
                if (!readString.IsSuccess) return OperateResult.CreateFailedResult<string>(readString);

                return OperateResult.CreateSuccessResult(Encoding.ASCII.GetString(readString.Content, 2, readString.Content.Length - 2));
            }
            else
            {
                var read = Read(address, 1);
                if (!read.IsSuccess) return OperateResult.CreateFailedResult<string>(read);

                var readString = Read(address, (ushort)(1 + read.Content[0]));
                if (!readString.IsSuccess) return OperateResult.CreateFailedResult<string>(readString);

                return OperateResult.CreateSuccessResult(Encoding.ASCII.GetString(readString.Content, 1, readString.Content.Length - 1));
            }
        }

        #endregion

        #region Head Codes

        private byte[] plcHead1 = new byte[22]
        {
            0x03,0x00,0x00,0x16,0x11,0xE0,0x00,0x00,0x00,0x01,0x00,0xC0,0x01,0x0A,0xC1,0x02,
            0x01,0x02,0xC2,0x02,0x01,0x00
        };
        private byte[] plcHead2 = new byte[25]
        {
            0x03,0x00,0x00,0x19,0x02,0xF0,0x80,0x32,0x01,0x00,0x00,0x04,0x00,0x00,0x08,0x00,
            0x00,0xF0,0x00,0x00,0x01,0x00,0x01,0x01,0xE0
        };
        private byte[] plcOrderNumber = new byte[]
        {
            0x03,0x00,0x00,0x21,0x02,0xF0,0x80,0x32,0x07,0x00,0x00,0x00,0x01,0x00,0x08,0x00,
            0x08,0x00,0x01,0x12,0x04,0x11,0x44,0x01,0x00,0xFF,0x09,0x00,0x04,0x00,0x11,0x00,
            0x00
        };
        private SiemensPLCS CurrentPlc = SiemensPLCS.S1200;
        private byte[] plcHead1_200smart = new byte[22]
        {
            0x03,0x00,0x00,0x16,0x11,0xE0,0x00,0x00,0x00,0x01,0x00,0xC1,0x02,0x10,0x00,0xC2,
            0x02,0x03,0x00,0xC0,0x01,0x0A
        };
        private byte[] plcHead2_200smart = new byte[25]
        {
            0x03,0x00,0x00,0x19,0x02,0xF0,0x80,0x32,0x01,0x00,0x00,0xCC,0xC1,0x00,0x08,0x00,
            0x00,0xF0,0x00,0x00,0x01,0x00,0x01,0x03,0xC0
        };

        private byte[] plcHead1_200 = new byte[]
        {
            0x03,0x00,0x00,0x16,0x11,0xE0,0x00,0x00,0x00,0x01,0x00,0xC1,0x02,0x4D,0x57,0xC2,
            0x02,0x4D,0x57,0xC0,0x01,0x09
        };
        private byte[] plcHead2_200 = new byte[]
        {
            0x03,0x00,0x00,0x19,0x02,0xF0,0x80,0x32,0x01,0x00,0x00,0x00,0x00,0x00,0x08,0x00,
            0x00,0xF0,0x00,0x00,0x01,0x00,0x01,0x03,0xC0
        };

        byte[] S7_STOP = {
            0x03, 0x00, 0x00, 0x21, 0x02, 0xf0, 0x80, 0x32, 0x01, 0x00, 0x00, 0x0e, 0x00, 0x00, 0x10, 0x00,
            0x00, 0x29, 0x00, 0x00, 0x00, 0x00, 0x00, 0x09, 0x50, 0x5f, 0x50, 0x52, 0x4f, 0x47, 0x52, 0x41,
            0x4d
        };

        byte[] S7_HOT_START = {
            0x03, 0x00, 0x00, 0x25, 0x02, 0xf0, 0x80, 0x32, 0x01, 0x00, 0x00, 0x0c, 0x00, 0x00, 0x14, 0x00,
            0x00, 0x28, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0xfd, 0x00, 0x00, 0x09, 0x50, 0x5f, 0x50, 0x52,
            0x4f, 0x47, 0x52, 0x41, 0x4d
        };

        byte[] S7_COLD_START = {
            0x03, 0x00, 0x00, 0x27, 0x02, 0xf0, 0x80, 0x32, 0x01, 0x00, 0x00, 0x0f, 0x00, 0x00, 0x16, 0x00,
            0x00, 0x28, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0xfd, 0x00, 0x02, 0x43, 0x20, 0x09, 0x50, 0x5f,
            0x50, 0x52, 0x4f, 0x47, 0x52, 0x41, 0x4d
        };

        #endregion

        #region Private Member

        private byte plc_rack = 0x00;
        private byte plc_slot = 0x00;

        const byte pduStart = 0x28;            // CPU start
        const byte pduStop = 0x29;             // CPU stop
        const byte pduAlreadyStarted = 0x02;   // CPU already in run mode
        const byte pduAlreadyStopped = 0x07;   // CPU already in stop mode

        #endregion

        #region Object Override

        /// <summary>
        /// 返回表示当前对象的字符串 -> Returns a String representing the current object
        /// </summary>
        /// <returns>字符串信息 -> String information</returns>
        public override string ToString()
        {
            return $"SiemensS7Net {CurrentPlc}[{IpAddress}:{Port}]";
        }

        #endregion

        #region Build Command

        /// <summary>
        /// A general method for generating a command header to read a Word data
        /// </summary>
        /// <param name="s7Addresses">siemens address</param>
        /// <returns>Message containing the result object</returns>
        public static OperateResult<byte[]> BuildReadCommand(S7AddressData[] s7Addresses)
        {
            if (s7Addresses == null) throw new NullReferenceException("s7Addresses");
            if (s7Addresses.Length > 19) throw new Exception(StringResources.Language.SiemensReadLengthCannotLargerThan19);

            int readCount = s7Addresses.Length;
            byte[] _PLCCommand = new byte[19 + readCount * 12];
            // ======================================================================================
            _PLCCommand[0] = 0x03;                                                // 报文头 -> Head
            _PLCCommand[1] = 0x00;
            _PLCCommand[2] = (byte)(_PLCCommand.Length / 256);                    // 长度 -> Length
            _PLCCommand[3] = (byte)(_PLCCommand.Length % 256);
            _PLCCommand[4] = 0x02;                                                // 固定 -> Fixed
            _PLCCommand[5] = 0xF0;
            _PLCCommand[6] = 0x80;
            _PLCCommand[7] = 0x32;                                                // 协议标识 -> Protocol identification
            _PLCCommand[8] = 0x01;                                                // 命令:发 -> Command: Send
            _PLCCommand[9] = 0x00;                                                // redundancy identification (reserved): 0x0000;
            _PLCCommand[10] = 0x00;                                               // protocol data unit reference; it’s increased by request event;
            _PLCCommand[11] = 0x00;
            _PLCCommand[12] = 0x01;                                               // 参数命令数据总长度 -> Parameter command Data total length
            _PLCCommand[13] = (byte)((_PLCCommand.Length - 17) / 256);
            _PLCCommand[14] = (byte)((_PLCCommand.Length - 17) % 256);
            _PLCCommand[15] = 0x00;                                               // 读取内部数据时为00,读取CPU型号为Data数据长度 -> Read internal data is 00, read CPU model is data length
            _PLCCommand[16] = 0x00;
            // =====================================================================================
            _PLCCommand[17] = 0x04;                                               // 读写指令,04读,05写 -> Read-write instruction, 04 read, 05 Write
            _PLCCommand[18] = (byte)readCount;                                    // 读取数据块个数 -> Number of data blocks read

            for (int ii = 0; ii < readCount; ii++)
            {
                //===========================================================================================
                // 指定有效值类型 -> Specify a valid value type
                _PLCCommand[19 + ii * 12] = 0x12;
                // 接下来本次地址访问长度 -> The next time the address access length
                _PLCCommand[20 + ii * 12] = 0x0A;
                // 语法标记,ANY -> Syntax tag, any
                _PLCCommand[21 + ii * 12] = 0x10;
                // 按字为单位 -> by word
                _PLCCommand[22 + ii * 12] = 0x02; // (byte)(address[ii].Content1 == 0x1D ? 0x1D : address[ii].Content1 == 0x1C ? 0x1C : 0x02);
                // 访问数据的个数 -> Number of Access data
                _PLCCommand[23 + ii * 12] = (byte)(s7Addresses[ii].Length / 256);
                _PLCCommand[24 + ii * 12] = (byte)(s7Addresses[ii].Length % 256);
                // DB块编号,如果访问的是DB块的话 -> DB block number, if you are accessing a DB block
                _PLCCommand[25 + ii * 12] = (byte)(s7Addresses[ii].DbBlock / 256);
                _PLCCommand[26 + ii * 12] = (byte)(s7Addresses[ii].DbBlock % 256);
                // 访问数据类型 -> Accessing data types
                _PLCCommand[27 + ii * 12] = s7Addresses[ii].DataCode;
                // 偏移位置 -> Offset position
                _PLCCommand[28 + ii * 12] = (byte)(s7Addresses[ii].AddressStart / 256 / 256 % 256);
                _PLCCommand[29 + ii * 12] = (byte)(s7Addresses[ii].AddressStart / 256 % 256);
                _PLCCommand[30 + ii * 12] = (byte)(s7Addresses[ii].AddressStart % 256);
            }

            return OperateResult.CreateSuccessResult(_PLCCommand);
        }

        /// <summary>
        /// 生成一个位读取数据指令头的通用方法 ->
        /// A general method for generating a bit-read-Data instruction header
        /// </summary>
        /// <param name="address">起始地址,例如M100.0,I0.1,Q0.1,DB2.100.2 ->
        /// Start address, such as M100.0,I0.1,Q0.1,DB2.100.2
        /// </param>
        /// <returns>包含结果对象的报文 -> Message containing the result object</returns>
        public static OperateResult<byte[]> BuildBitReadCommand(string address)
        {
            OperateResult<S7AddressData> analysis = S7AddressData.ParseFrom(address);
            if (!analysis.IsSuccess) return OperateResult.CreateFailedResult<byte[]>(analysis);

            byte[] _PLCCommand = new byte[31];
            _PLCCommand[0] = 0x03;
            _PLCCommand[1] = 0x00;
            // 长度 -> Length
            _PLCCommand[2] = (byte)(_PLCCommand.Length / 256);
            _PLCCommand[3] = (byte)(_PLCCommand.Length % 256);
            // 固定 -> Fixed
            _PLCCommand[4] = 0x02;
            _PLCCommand[5] = 0xF0;
            _PLCCommand[6] = 0x80;
            _PLCCommand[7] = 0x32;
            // 命令:发 -> command to send
            _PLCCommand[8] = 0x01;
            // 标识序列号
            _PLCCommand[9] = 0x00;
            _PLCCommand[10] = 0x00;
            _PLCCommand[11] = 0x00;
            _PLCCommand[12] = 0x01;
            // 命令数据总长度 -> Identification serial Number
            _PLCCommand[13] = (byte)((_PLCCommand.Length - 17) / 256);
            _PLCCommand[14] = (byte)((_PLCCommand.Length - 17) % 256);

            _PLCCommand[15] = 0x00;
            _PLCCommand[16] = 0x00;

            // 命令起始符 -> Command start character
            _PLCCommand[17] = 0x04;
            // 读取数据块个数 -> Number of data blocks read
            _PLCCommand[18] = 0x01;

            //===========================================================================================
            // 读取地址的前缀 -> Read the prefix of the address
            _PLCCommand[19] = 0x12;
            _PLCCommand[20] = 0x0A;
            _PLCCommand[21] = 0x10;
            // 读取的数据时位 -> Data read-time bit
            _PLCCommand[22] = 0x01;
            // 访问数据的个数 -> Number of Access data
            _PLCCommand[23] = 0x00;
            _PLCCommand[24] = 0x01;
            // DB块编号,如果访问的是DB块的话 -> DB block number, if you are accessing a DB block
            _PLCCommand[25] = (byte)(analysis.Content.DbBlock / 256);
            _PLCCommand[26] = (byte)(analysis.Content.DbBlock % 256);
            // 访问数据类型 -> Types of reading data
            _PLCCommand[27] = analysis.Content.DataCode;
            // 偏移位置 -> Offset position
            _PLCCommand[28] = (byte)(analysis.Content.AddressStart / 256 / 256 % 256);
            _PLCCommand[29] = (byte)(analysis.Content.AddressStart / 256 % 256);
            _PLCCommand[30] = (byte)(analysis.Content.AddressStart % 256);

            return OperateResult.CreateSuccessResult(_PLCCommand);
        }

        /// <summary>
        /// 生成一个写入字节数据的指令 -> Generate an instruction to write byte data
        /// </summary>
        /// <param name="analysis">起始地址,示例M100,I100,Q100,DB1.100 -> Start Address, example M100,I100,Q100,DB1.100</param>
        /// <param name="data">原始的字节数据 -> Raw byte data</param>
        /// <returns>包含结果对象的报文 -> Message containing the result object</returns>
        public static OperateResult<byte[]> BuildWriteByteCommand(OperateResult<S7AddressData> analysis, byte[] data)
        {
            byte[] _PLCCommand = new byte[35 + data.Length];
            _PLCCommand[0] = 0x03;
            _PLCCommand[1] = 0x00;
            // 长度 -> Length
            _PLCCommand[2] = (byte)((35 + data.Length) / 256);
            _PLCCommand[3] = (byte)((35 + data.Length) % 256);
            // 固定 -> Fixed
            _PLCCommand[4] = 0x02;
            _PLCCommand[5] = 0xF0;
            _PLCCommand[6] = 0x80;
            _PLCCommand[7] = 0x32;
            // 命令 发 -> command to send
            _PLCCommand[8] = 0x01;
            // 标识序列号 -> Identification serial Number
            _PLCCommand[9] = 0x00;
            _PLCCommand[10] = 0x00;
            _PLCCommand[11] = 0x00;
            _PLCCommand[12] = 0x01;
            // 固定 -> Fixed
            _PLCCommand[13] = 0x00;
            _PLCCommand[14] = 0x0E;
            // 写入长度+4 -> Write Length +4
            _PLCCommand[15] = (byte)((4 + data.Length) / 256);
            _PLCCommand[16] = (byte)((4 + data.Length) % 256);
            // 读写指令 -> Read and write instructions
            _PLCCommand[17] = 0x05;
            // 写入数据块个数 -> Number of data blocks written
            _PLCCommand[18] = 0x01;
            // 固定,返回数据长度 -> Fixed, return data length
            _PLCCommand[19] = 0x12;
            _PLCCommand[20] = 0x0A;
            _PLCCommand[21] = 0x10;
            // 写入方式,1是按位,2是按字 -> Write mode, 1 is bitwise, 2 is by word
            _PLCCommand[22] = 0x02;
            // 写入数据的个数 -> Number of Write Data
            _PLCCommand[23] = (byte)(data.Length / 256);
            _PLCCommand[24] = (byte)(data.Length % 256);
            // DB块编号,如果访问的是DB块的话 -> DB block number, if you are accessing a DB block
            _PLCCommand[25] = (byte)(analysis.Content.DbBlock / 256);
            _PLCCommand[26] = (byte)(analysis.Content.DbBlock % 256);
            // 写入数据的类型 -> Types of writing data
            _PLCCommand[27] = analysis.Content.DataCode;
            // 偏移位置 -> Offset position
            _PLCCommand[28] = (byte)(analysis.Content.AddressStart / 256 / 256 % 256); ;
            _PLCCommand[29] = (byte)(analysis.Content.AddressStart / 256 % 256);
            _PLCCommand[30] = (byte)(analysis.Content.AddressStart % 256);
            // 按字写入 -> Write by Word
            _PLCCommand[31] = 0x00;
            _PLCCommand[32] = 0x04;
            // 按位计算的长度 -> The length of the bitwise calculation
            _PLCCommand[33] = (byte)(data.Length * 8 / 256);
            _PLCCommand[34] = (byte)(data.Length * 8 % 256);

            data.CopyTo(_PLCCommand, 35);

            return OperateResult.CreateSuccessResult(_PLCCommand);
        }

        /// <summary>
        /// 生成一个写入位数据的指令 -> Generate an instruction to write bit data
        /// </summary>
        /// <param name="address">起始地址,示例M100,I100,Q100,DB1.100 -> Start Address, example M100,I100,Q100,DB1.100</param>
        /// <param name="data">是否通断 -> Power on or off</param>
        /// <returns>包含结果对象的报文 -> Message containing the result object</returns>
        public static OperateResult<byte[]> BuildWriteBitCommand(string address, bool data)
        {
            OperateResult<S7AddressData> analysis = S7AddressData.ParseFrom(address);
            if (!analysis.IsSuccess) return OperateResult.CreateFailedResult<byte[]>(analysis);

            byte[] buffer = new byte[1];
            buffer[0] = data ? (byte)0x01 : (byte)0x00;

            byte[] _PLCCommand = new byte[35 + buffer.Length];
            _PLCCommand[0] = 0x03;
            _PLCCommand[1] = 0x00;
            // 长度 -> length
            _PLCCommand[2] = (byte)((35 + buffer.Length) / 256);
            _PLCCommand[3] = (byte)((35 + buffer.Length) % 256);
            // 固定 -> fixed
            _PLCCommand[4] = 0x02;
            _PLCCommand[5] = 0xF0;
            _PLCCommand[6] = 0x80;
            _PLCCommand[7] = 0x32;
            // 命令 发 -> command to send
            _PLCCommand[8] = 0x01;
            // 标识序列号 -> Identification serial Number
            _PLCCommand[9] = 0x00;
            _PLCCommand[10] = 0x00;
            _PLCCommand[11] = 0x00;
            _PLCCommand[12] = 0x01;
            // 固定 -> fixed
            _PLCCommand[13] = 0x00;
            _PLCCommand[14] = 0x0E;
            // 写入长度+4 -> Write Length +4
            _PLCCommand[15] = (byte)((4 + buffer.Length) / 256);
            _PLCCommand[16] = (byte)((4 + buffer.Length) % 256);
            // 命令起始符 -> Command start character
            _PLCCommand[17] = 0x05;
            // 写入数据块个数 -> Number of data blocks written
            _PLCCommand[18] = 0x01;
            _PLCCommand[19] = 0x12;
            _PLCCommand[20] = 0x0A;
            _PLCCommand[21] = 0x10;
            // 写入方式,1是按位,2是按字 -> Write mode, 1 is bitwise, 2 is by word
            _PLCCommand[22] = 0x01;
            // 写入数据的个数 -> Number of Write Data
            _PLCCommand[23] = (byte)(buffer.Length / 256);
            _PLCCommand[24] = (byte)(buffer.Length % 256);
            // DB块编号,如果访问的是DB块的话 -> DB block number, if you are accessing a DB block
            _PLCCommand[25] = (byte)(analysis.Content.DbBlock / 256);
            _PLCCommand[26] = (byte)(analysis.Content.DbBlock % 256);
            // 写入数据的类型 -> Types of writing data
            _PLCCommand[27] = analysis.Content.DataCode;
            // 偏移位置 -> Offset position
            _PLCCommand[28] = (byte)(analysis.Content.AddressStart / 256 / 256);
            _PLCCommand[29] = (byte)(analysis.Content.AddressStart / 256);
            _PLCCommand[30] = (byte)(analysis.Content.AddressStart % 256);
            // 按位写入 -> Bitwise Write
            _PLCCommand[31] = 0x00;
            _PLCCommand[32] = 0x03;
            // 按位计算的长度 -> The length of the bitwise calculation
            _PLCCommand[33] = (byte)(buffer.Length / 256);
            _PLCCommand[34] = (byte)(buffer.Length % 256);

            buffer.CopyTo(_PLCCommand, 35);

            return OperateResult.CreateSuccessResult(_PLCCommand);
        }


        #endregion

    }
}